Obo Betterman Kombinovani odvodnik prenapona i gromobranski odvodnik Tip 1+2, 3-polni + NPE 5093654

Obo Betterman Kombinovani odvodnik prenapona i gromobranski odvodnik Tip 1+2, 3-polni + NPE 5093654

The combination lightning and surge arrester Type 1+2 (catalog number 5093654) is designed to protect electrical installations against lightning strikes and transient...

Brand: Obo Betterman
Product Code: 5093654
Availability: In stock
VAT-exclusive price: 32.330,43
VAT-inclusive price: 38.796,51

The combination lightning and surge arrester Type 1+2 (catalog number 5093654) is designed to protect electrical installations against lightning strikes and transient overvoltages in accordance with DIN EN 61643-11 and IEC 61643-1 (Class I+II).

It is intended for equipotential bonding in buildings, including those equipped with external lightning protection systems (Class III and IV). Suitable for TN and TT network systems, the device is mounted on a 35 mm DIN rail.

The arrester provides a lightning current discharge capacity of 12.5 kA (10/350 µs) per pole and 50 kA total, with a protection level below 1.3 kV. It features the new Multibase base with multi-connection terminals, visual status indication, and is supplied as a complete ready-to-connect unit (base + plug-in module).

The encapsulated, non-extinguishing zinc oxide varistor makes it ideal for installation inside distribution boards.


 

Parameter Value
Product Type Combination Lightning & Surge Arrester
SPD according to EN 61643-11 Type 1+2
SPD according to IEC 61643-1 Class I+II
Version 3+NPE
Pole Number 3
Pole Version 3
Nominal Voltage AC (50/60 Hz) 230 V
Maximum Continuous Voltage AC 280 V
Maximum Continuous Voltage (N-PE) 255 V
Dimension 280 V
Lightning Surge Current (10/350 µs) per Pole 12.5 kA
Total Lightning Surge Current (10/350 µs) 50 kA
Arrester Surge Current (8/20 µs) Total 50 kA
Maximum Discharge Current (8/20 µs) 50 kA
Nominal Discharge Current (8/20 µs) 30 kA
Nominal Discharge Current (8/20 µs) [L-N] 30 kA
Nominal Discharge Current (8/20 µs) [N-PE] 50 kA
Protection Level [L-N] ≤ 1.3 kV
Response Time < 25 ns
Protection Rating IP20
Installation Type DIN Rail 35 mm
Operating Temperature (min/max) -40 °C to +80 °C
Permitted Temperature Range (min/max) -40 °C to +80 °C
Max. Mains-side Overcurrent Protection 125 A
Maximum Back-up Fuse 125 A
Integrated Back-up Fuse No
Conductor Cross-section (min) 2.5 mm²
Conductor Cross-section (max) 35 mm²
Lightning Protection Zone LPZ 0 → 2
TN Network Form Yes
TN-C Network Form No
TN-S Network Form Yes
TN-C-S Network Form Yes
TT Network Form Yes
IT Network Form No
DC Network Form No
Other Network Form No
Remote Signalling No
Signalling on Device Visual
Blow-out No
CO₂ Footprint (GWP Cradle-to-Gate) 1.7832 kg CO₂e / piece

Similar products:


Obo Betterman Odvodnik prenapona 3+1 za 280V | 5094656

The 3+1 Type 2 surge arrester consists of an upper part and base, pre-mounted and ready for connection. Suitable for TN and TT network systems, with visual defect
-
In stock

(In stock)

 
 
8.412,60

Obo Betterman Odvodnik prenapona 3+N/PE sa daljinskim signaliziranjem 280V - Type 2 | 5094765

The 3+N/PE Type 2 surge arrester consists of an upper part and base, pre-mounted and ready for connection. Suitable for TN and TT network systems, it features visual
-
In stock

(In stock)

 
 
10.277,77

Obo Betterman 2-polni odvodnik prenapona za fotovoltaik, 1000V DC | 5094617

The V20 2-pole surge arrester is a Type 2 device for directly earthed photovoltaic systems. It consists of a varistor arrester with a cut-off unit and visual function
-
In stock

(In stock)

 
 
10.781,18

Obo Betterman Kombinovani gromobranski i prenaponski odvodnik Tip 1+2, 3-polni + NPE sa daljinskom signalizacijom (FS) | 5093662

The combination lightning and surge arrester Type 1+2 with remote signalling (catalog number 5093662) is designed to protect electrical installations against direct
-
In stock

(In stock)

 
 
34.001,20

1
2
3
Compare products Remove all products