Schneider Electric Induktivni senzor XS6 M18 - L61mm - mesing - Sn8mm - 12..48VDC - kabl 10m;XS618B1PAL10EX
Inductive proximity sensors XS ATEX D, inductive sensor hazardous area, M18, Sn8mm, 12...48 VDC, NO, cable 10 m...
VAT-exclusive price: 17.072,00 |
VAT-inclusive price: 20.486,40 |
Inductive proximity sensors XS ATEX D, inductive sensor hazardous area, M18, Sn8mm, 12...48 VDC, NO, cable 10 m
| range of product | Telemecanique Inductive proximity sensors XS |
|---|---|
| series name | Application |
| sensor type | Inductive proximity sensor |
| device application | ATEX dust |
| sensor name | XS6 |
| sensor design | Cylindrical M18 |
| size | 18 mm |
| body type | Fixed |
| detector flush mounting acceptance | Flush mountable |
| material | Metal |
| enclosure material | Nickel plated brass |
| [Sn] nominal sensing distance | 8 mm |
| type of output signal | Discrete |
| wiring technique | 3-wire |
| discrete output function | 1 NO |
| output circuit type | DC |
| discrete output type | PNP |
| electrical connection | Cable |
| cable length | 10 m |
| [Us] rated supply voltage | 12...48 V DC with reverse polarity protection |
| switching capacity in mA | <= 200 mA with overload and short-circuit protection |
| IP degree of protection |
IP68 conforming to IEC 60529 IP69K |
| thread type | M18 x 1 |
|---|---|
| detection face | Frontal |
| front material | PPS |
| sensing range | > 4...8 mm |
| operating zone | 0…6.4 mm |
| differential travel | 1...15% of Sr |
| cable composition | 3 x 0.34 mm² |
| wire insulation material | PvR |
| status LED | Output state: 1 LED (yellow) |
| supply voltage limits | 10…58 V DC |
| switching frequency | <= 1000 Hz |
| maximum voltage drop | <2 V (closed state) |
| current consumption | <= 10 mA no-load |
| maximum delay first up | 10 ms |
| maximum delay response | 0.3 ms |
| maximum delay recovery | 0.7 ms |
| marking | II2 D-Ex tb IIIC T90°C Db IP68 |
| threaded length | 51 mm |
| length | 61 mm |
| environmental characteristic | Hazardous location |
|---|---|
| standards |
EN/IEC 60079-31 EN/IEC 60079-0 |
| directives | 2014/34/EU - ATEX directive |
| product certifications |
IEC-Ex INE 17.0006 INERIS 04ATEX0022X |
| ambient air temperature for operation | -20…60 °C |
| vibration resistance | 25 gn amplitude = +/- 2 mm (f = 10…55 Hz) conforming to IEC 60068-2-6 |
| shock resistance | 50 gn for 11 ms conforming to IEC 60068-2-27 |
| dust zone | Zone 21 - 22 |
| Unit Type of Package 1 | PCE |
|---|---|
| Package 1 Length | 15.0 cm |
| Number of Units in Package 1 | 1 |
| Package 2 Width | 30.0 cm |
| Package 2 Height | 15.0 cm |
| Package 2 Weight | 3.813 kg |
| Package 1 Width | 15.0 cm |
| Package 1 Height | 6.0 cm |
| Package 1 Weight | 341.0 g |
| Number of Units in Package 2 | 10 |
| Unit Type of Package 2 | S02 |
| Package 2 Length | 40.0 cm |
| Warranty | 18 months |
|---|